We only make claims we can support with a document, data or a clear process. Each reason below links to the proof.
Engineered solutions
Systems are recommended from the project's actual requirements — exposure, opening sizes, use and budget — not pushed from a fixed list.
See our processTested materials
The uPVC profile material has independent laboratory reports from Shriram Institute, CIPET Haldia and SGS India, each linked in full.
View test reportsCustomisation
Windows and doors fabricated to each opening; railings, façades, fins and louvers developed from your drawings.
Custom projectsArchitectural focus
Window, railing, façade and shading systems that work together on one elevation.
Explore productsEnd-to-end support
One team from requirement and consultation through quotation, installation and handover.
How we workTransparent communication
Published profile data, clearly marked unknowns, and quotations based on your real requirement.
Technical resourcesEvidence
Tested materials, in numbers.
43MPa
Tensile strength
Resistance to being pulled apart — an indicator of everyday durability of the profile material.
Shriram Institute report0.5%
Heat reversion
Dimensional change after heating (method reference: EN 12608). Low values mean the profile stays dimensionally stable in heat.
Shriram Institute report0.234W/mK
Thermal conductivity
How readily heat passes through the material. This is a material property, not a window U-value.
Shriram Institute report73.37kJ/m²
Notched Charpy impact
Energy absorbed when a notched sample is struck — a measure of impact toughness.
Shriram Institute reportV-0
Vertical flammability (UL-94)
Classification of how a sample stops burning in a vertical test. V-0 does not mean the product is fireproof.
Shriram Institute reportMaterial test result ≠ installed system performance. These are laboratory results for samples of the uPVC profile material, valid under the stated test conditions. They are not a guarantee of installed window performance, which also depends on glass, hardware, reinforcement, fabrication and installation.
Project references & testimonials
Client testimonials and documented case studies are published only with written consent and real photography. Ask the team for references relevant to your project.
View projectsStart a conversation
Have a project in mind?
Tell us what you're building. We'll help you choose the right solution.
Prefer to talk? Call +91 9220420757 or email info@trimatrixbuildtech.com.