Strong & Durable
43 MPa
Tensile Strength
Tested for tensile strength to demonstrate the material's ability to handle mechanical stress.
Shriram Institute for Industrial Research
View Test Report →Premium building products for homes, offices, and commercial projects.

Energy-saving, low-maintenance, weather-protected window and door systems with strong thermal and acoustic performance.

Sleek, high-strength systems for luxury homes, commercial spaces, and high-rise projects with maximum natural light.

Durable, corrosion-resistant railing solutions with modern finishes and customizable design options.

Weather-resistant façade systems for stylish exteriors, improved insulation, and strong architectural impact.

Supportive architectural profile systems designed for performance, aesthetics, and precision installation.

Tailored design and manufacturing for residential, commercial, and industrial projects of any scale or complexity.
Independent laboratory evidence
Our uPVC profiles have been independently tested for key properties such as strength, impact resistance, thermal stability, colour performance, fire behaviour and restricted substances. These tests provide measurable evidence of material performance under defined laboratory conditions.
Independently Tested · Measured Performance · Quality Focused
43 MPa
Tensile Strength
Tested for tensile strength to demonstrate the material's ability to handle mechanical stress.
Shriram Institute for Industrial Research
View Test Report →73.37 kJ/m²
Notched Charpy Impact
Tested for resistance to sudden impact and material toughness.
No brittle failure observed at −10°C
Shriram Institute for Industrial Research
View Test Report →0.5%
Heat Reversion
Low heat reversion helps the profile maintain dimensional stability under the specified test conditions.
Tested according to EN 12608
Shriram Institute for Industrial Research
View Test Report →150°C / 30 min
After the specified laboratory heat exposure, no visible blisters, cavities, cracks or delamination were observed.
Shriram Institute for Industrial Research
View Test Report →UL-94 V-0
Achieved V-0 classification under the specified vertical flammability test conditions.
V-0 is a material flammability classification and does not mean the product is fireproof.
Shriram Institute for Industrial Research
View Test Report →LOI 45%
Limiting Oxygen Index
Indicates the oxygen concentration required to sustain combustion under the specified test conditions.
Shriram Institute for Industrial Research
View Test Report →Rating 6
Colour Fastness
Tested for colour stability under accelerated weathering conditions.
Designed to help maintain its appearance over time.
Shriram Institute for Industrial Research
View Test Report →0.234 W/mK
Thermal Conductivity
uPVC has relatively low thermal conductivity compared with many conventional metals, supporting thermal comfort when used as part of a properly designed window system.
Shriram Institute for Industrial Research
View Test Report →49 MPa
Flexural Strength
Tested for strength and rigidity to support the structural performance of the profile material.
2524 MPa · Flexural Modulus
Shriram Institute for Industrial Research
View Test Report →81 Shore D
Tested for surface hardness using the Shore D method.
CIPET Haldia
View Test Report →1.50 g/cc
Shriram
Independent laboratory testing reported closely matching density values for the tested samples.
1.52 g/cc · CIPET Haldia
Shriram Institute for Industrial Research
View Test Report →Responsible Material Testing
SGS testing found the tested sample compliant with the specified RoHS requirements for restricted substances, including cadmium, lead, mercury, hexavalent chromium, PBBs, PBDEs, DEHP, BBP, DBP and DIBP.
SGS testing detected 8.5 mg/kg of lead in the tested sample. The applicable RoHS limit shown in the report is 1000 mg/kg, and the sample received a PASS result for the specified RoHS testing.
SGS India Pvt. Ltd. · Report No. MAN:HL:1548004308
Tested heat-reversion performance helps the profile maintain dimensional stability under the specified test conditions.
Mechanical and impact testing provides measurable evidence of material strength and toughness.
No brittle failure was observed during the specified −10°C impact test.
Accelerated weathering testing achieved Colour Fastness Rating 6.
The tested material achieved UL-94 V-0 under the specified test conditions.
Mechanical · Thermal · Impact · Fire · Weathering
Tensile 43 MPa · Heat Reversion 0.5% · Charpy 73.37 kJ/m² · UL-94 V-0 · LOI 45% · Colour Fastness 6
Physical Properties Testing
Density 1.52 g/cc · Hardness 81 Shore D. Results relate only to the submitted samples.
Restricted Substance / RoHS Testing
RoHS — PASS · Lead 8.5 mg/kg. Results refer to the sample tested.
Tensile Strength — 43 MPa Elongation — 128% Flexural Strength — 49 MPa Flexural Modulus — 2524 MPa Hardness — 81 Shore D
Vicat Softening Temperature — 79°C Heat Reversion — 0.5% Thermal Conductivity — 0.234 W/mK Heat Ageing — 150°C / 30 minutes
Notched Charpy Impact — 73.37 kJ/m² Izod Impact — 1010 J/m Low-temperature impact — No brittle failure at −10°C
UL-94 — V-0 Limiting Oxygen Index — 45%
Colour Fastness — Rating 6 Sulphuric Acid Resistance — 0.12 g weight increase RoHS — PASS Lead — 8.5 mg/kg in SGS-tested sample
Density — 1.50 g/cc — Shriram Density — 1.52 g/cc — CIPET Hardness — 81 Shore D — CIPET
Want to see the original reports? View the laboratory documents directly.
From strength and impact resistance to thermal stability, colour performance and restricted-substance testing, our uPVC profile performance is supported by measurable laboratory results.
Tell us about your project and we'll provide a customized quote.