Independent laboratory evidence
Built to perform. Tested to verify.
20 results for the uPVC profile material from three independent laboratories — each with its original report.
43MPa
Tensile strength
Resistance to being pulled apart — an indicator of everyday durability of the profile material.
Shriram Institute report0.5%
Heat reversion
Dimensional change after heating (method reference: EN 12608). Low values mean the profile stays dimensionally stable in heat.
Shriram Institute report0.234W/mK
Thermal conductivity
How readily heat passes through the material. This is a material property, not a window U-value.
Shriram Institute report73.37kJ/m²
Notched Charpy impact
Energy absorbed when a notched sample is struck — a measure of impact toughness.
Shriram Institute reportV-0
Vertical flammability (UL-94)
Classification of how a sample stops burning in a vertical test. V-0 does not mean the product is fireproof.
Shriram Institute reportMaterial test result ≠ installed system performance. These are laboratory results for samples of the uPVC profile material, valid under the stated test conditions. They are not a guarantee of installed window performance, which also depends on glass, hardware, reinforcement, fabrication and installation.
Technical test details
All results
Grouped by property. Each laboratory name links to the report the result comes from.
Mechanical
| Property | Result | What it means | Laboratory |
|---|---|---|---|
| Tensile strength | 43 MPa | Resistance to being pulled apart — an indicator of everyday durability of the profile material. | Shriram Institute |
| Elongation | 128 % | How far the material stretches before breaking — indicates toughness rather than brittleness. | Shriram Institute |
| Flexural strength | 49 MPa | Resistance to bending under load. | Shriram Institute |
| Flexural modulus | 2524 MPa | Stiffness of the material — how much it resists flexing. | Shriram Institute |
Thermal
| Property | Result | What it means | Laboratory |
|---|---|---|---|
| Vicat softening temperature | 79 °C | Temperature at which the material begins to soften under a standard load. | Shriram Institute |
| Heat reversion | 0.5 % | Dimensional change after heating (method reference: EN 12608). Low values mean the profile stays dimensionally stable in heat. | Shriram Institute |
| Heat ageing | 150 °C / 30 min | No visible blisters, cavities, cracks or delamination reported after heat exposure. | Shriram Institute |
| Thermal conductivity | 0.234 W/mK | How readily heat passes through the material. This is a material property, not a window U-value. | Shriram Institute |
Impact
| Property | Result | What it means | Laboratory |
|---|---|---|---|
| Notched Charpy impact | 73.37 kJ/m² | Energy absorbed when a notched sample is struck — a measure of impact toughness. | Shriram Institute |
| Izod impact | 1010 J/m | A second impact-toughness method. | Shriram Institute |
| Low-temperature impact | No brittle failure at −10 °C | The material remained tough rather than brittle at low temperature. | Shriram Institute |
Fire
| Property | Result | What it means | Laboratory |
|---|---|---|---|
| Vertical flammability (UL-94) | V-0 | Classification of how a sample stops burning in a vertical test. V-0 does not mean the product is fireproof. | Shriram Institute |
| Limiting oxygen index (LOI) | 45 % | Minimum oxygen concentration needed to sustain burning. Normal air is about 21% oxygen. | Shriram Institute |
Colour & Chemical
| Property | Result | What it means | Laboratory |
|---|---|---|---|
| Colour fastness (weathering) | Rating 6 | Resistance to colour change after a weathering test. | Shriram Institute |
| Sulphuric acid resistance | 0.12 g weight increase | Change in weight after exposure to sulphuric acid in the test. | Shriram Institute |
| RoHS (restricted substances) | PASS | Tested against cadmium, lead, mercury, hexavalent chromium, PBBs, PBDEs, DEHP, BBP, DBP and DIBP. | SGS India |
| Lead content | 8.5 mg/kg | Measured in the tested sample, against the RoHS limit of 1000 mg/kg. | SGS India |
Physical
| Property | Result | What it means | Laboratory |
|---|---|---|---|
| Density | 1.50 g/cc | Mass per volume of the profile material. | Shriram Institute |
| Density | 1.52 g/cc | Independent density measurement by a second laboratory. | CIPET Haldia |
| Surface hardness | 81 Shore D | Resistance to surface indentation. | CIPET Haldia |
In plain language
What these tests mean for you
Thermal stability
Heat reversion of 0.5% and heat ageing at 150 °C / 30 min with no visible defects reported indicate the profile holds its shape in heat.
Everyday durability
Tensile (43 MPa) and flexural (49 MPa) strength describe how the material resists pulling and bending loads.
Low-temperature impact
No brittle failure at −10 °C — the material stays tough rather than cracking on impact.
Colour stability
Colour fastness rating 6 after the weathering test describes resistance to colour change.
Flammability testing
UL-94 V-0 and LOI 45% describe how the material behaves in standard flame tests. They do not mean the product is fireproof.
Verify the results
Tested by independent laboratories
Shriram Institute for Industrial Research
Mechanical, thermal, impact, fire and weathering tests
View test reportMaterial test result ≠ installed system performance. These are laboratory results for samples of the uPVC profile material, valid under the stated test conditions. They are not a guarantee of installed window performance, which also depends on glass, hardware, reinforcement, fabrication and installation.
Start a conversation
Questions about the data?
Ask the Trimatrix team how these results apply to your project.
Prefer to talk? Call +91 9220420757 or email info@trimatrixbuildtech.com.